Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
3.
J Comput Assist Tomogr ; 47(3): 424-428, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37185006

RESUMO

BACKGROUND: Foreign body aspiration (FBA) in childhood is a life-threatening condition that necessitates prompt management to prevent devastating complications. Different imaging methods are used in the diagnosis of FBA. OBJECTIVE: The aim of this study was to compare the diagnostic value and dose of microsievert wide-volume computed tomography (µSv-WV-CT) with multidetector computed tomography using an automatic exposure control system (MDCT-AEC) in children with FBA. MATERIAL AND METHODS: In this single-center cross-sectional study, 102 cases diagnosed with FBA between September 2013 and September 2021 were retrospectively evaluated. The patients were divided into 2 groups according to the diagnostic modality used: group A, µSv-WV-CT (2016-2021) and group B, MDCT-AEC (2013-2021). The diagnostic performance and radiation dose of the 2 groups were statistically compared. RESULTS: The diagnostic performance (sensitivity, specificity, positive predictive value, negative predictive value, and accuracy) of the 2 groups was similar. The mean effective radiation dose of group A was 34.89 ± 0.01 µSv, which was significantly lower than that of group B (179.75 ± 114.88 µSv) ( P < 0.001). CONCLUSION: In children with suspected FBA, µSv-WV-CT at a lower radiation dose had similar diagnostic performance to MDCT-AEC.


Assuntos
Corpos Estranhos , Tomografia Computadorizada Espiral , Humanos , Criança , Estudos Retrospectivos , Estudos Transversais , Tomografia Computadorizada Multidetectores , Corpos Estranhos/diagnóstico por imagem , Doses de Radiação
5.
Int J Rheum Dis ; 26(5): 917-921, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36946548

RESUMO

OBJECTIVES: We aimed to quantitatively analyze lung parenchymal changes in Behçet's patients and to detect early parenchymal quantitative changes that occur in the absence of positive visual radiological findings. METHODS: In our study, a total of 31 patients with Behçet's disease, 17 with positive radiological findings and 14 patients without positive radiological findings, and a control group of 33 individuals were evaluated. The automatic program determined lung volumes, lung densities, and opacity volume percentages by evaluating the contrast-enhanced lung computed tomography scans. RESULTS: The total lung volume was 3632.98 ± 1100.53 mL in the Behçet's disease patient group and 4925.70 ± 1098.88 mL in the control group, and there was a significant decrease in the total lung volume in Behçet's disease patients (P < 0.0001). The mean lung density was -723.73 ± 65.16 in the Behçet's disease patient group and -767.35 ± 41.17 in the control group, and there was a significant increase in the mean density in the Behçet's patients (P = 0.0023). A significantly higher correlation was observed between lung density and lung volume in Behçet's patients (P < 0.0001, r = -0.795). The lung volume of Behçet's disease patients with negative radiological findings was significantly lower than that of the control group (P = 0.0342). CONCLUSIONS: Lung volumetric changes in Behçet's disease patients are the quantitative data most affected by the disease. In addition, lung volume decreases in Behçet's patients who do not have visual parenchymal involvement.


Assuntos
Síndrome de Behçet , Pneumopatias , Humanos , Síndrome de Behçet/diagnóstico , Pulmão , Tomografia Computadorizada por Raios X
6.
Iran J Pharm Res ; 21(1): e123824, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35765507

RESUMO

Iodine-based contrast agents have limitations such as rapid clearance, potential renal toxicity, non-specific blood pool distribution, headache, and adverse events. Nowadays, it is quite common to work with nanosized systems in order to eliminate the side effects of contrast agents. This study aims to synthesize a new iodinated contrast agent, prepare its nanosuspension by using the nanoprecipitation method, investigate its cytotoxicity, and compare its contrast properties with iohexol and iopromide through in-vitro experiments. The values of nanosuspension particle size and zeta potential have been found to be ~ 400 nm and ~ (-) 15 mV, respectively. In-vitro cellular viability findings indicated that the nanosuspension has lower cytotoxicity than the iohexol and iopromide. In the computed tomography (CT) imaging study of contrast features of nanosuspensions and two commercial agents, which involved 86 CT examinations using 31 parameters and two different devices, it was found that iodine had a stronger presence in its nanosuspension form than in iohexol and iopromide, which were the other two commercial contrast agents, when used in equal amounts. Thus in the case of nanosuspensions contrast brightness was achieved by using less iodine, while the same brightness could be obtained with higher doses of iohexol and iopromide. CT imaging therefore be done without much chemical use, which indicates that it may witness fewer side effects in the future.

9.
Pediatr Emerg Care ; 38(2): e443-e446, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35100748

RESUMO

OBJECTIVES: Ultrasonography in a child with suspected appendicitis is primarily performed to detect inflamed appendix, whereas secondary findings are important in patients with a nonvisualized appendix. The aim of this study is to evaluate the gallbladder wall thickness and volume in patients with suspected appendicitis and search an association between these parameters and appendicitis. METHODS: Between January 2018 and August 2018, 113 patients with suspected appendicitis were included in this prospective study. Gallbladder and right lower quadrant were evaluated in separate sessions by different radiologists. The wall thickness along with the width, length, and height of the gallbladder was measured and recorded for each patient. Assessment of the appendix was classified as acute appendicitis, normal, and equivocal. Statistically significant association was sought between the thickness of the gallbladder wall and diagnosis of appendicitis. RESULTS: Gallbladder wall thickness was significantly higher in patients without appendicitis (P = 0.017), whereas significantly increased gallbladder volume was observed in patients with appendicitis (P = 0.004). Receiver operating characteristic analysis showed gallbladder wall thickness threshold of 0.5 mm with a sensitivity of 83.3, specificity of 93.9, and volume threshold of 41.6 mL with a sensitivity of 100 and a specificity of 0.69. CONCLUSIONS: Gallbladder wall thickness and volume measurements were associated with the diagnosis of appendicitis in pediatric patients.


Assuntos
Apendicite , Apêndice , Apendicite/diagnóstico por imagem , Apêndice/diagnóstico por imagem , Criança , Vesícula Biliar/diagnóstico por imagem , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade
10.
Eurasian J Med ; 54(Suppl1): 10-15, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36655439

RESUMO

Alveolar echinococcosis is a life-threatening zoonotic disease caused by Echinococcus multilocularis. The disease usually primarily involves the liver and shows tumor-like growth. Early diagnosis of alveolar echinococcosis is difficult because the disease is usually asymptomatic in the early stages. Untreated cases are fatal and result in death within 10 years of liver involvement. In the diagnosis of alveolar echinococcosis, the patient's medical history, radiological imaging findings, and serological and histopathological tests are used together. Radiological imaging methods are very important for early diagnosis and differential diagnosis of the disease. In this article, we wanted to review the diagnosis and treatment of alveolar echinococcosis and emphasize the importance of keeping it in mind, especially in cystic lesions of the liver, and the importance of early diagnosis of the disease.

11.
Acta Radiol ; 63(2): 192-199, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33508953

RESUMO

BACKGROUND: The use and frequency of computed tomography (CT) are increasing day by day in emergency departments (ED). This increases the amount of radiation exposed. PURPOSE: To evaluate the image quality obtained by ultra-low-dose CT (ULDCT) in patients with suspected wrist fractures in the ED and to investigate whether it is an alternative to standard-dose CT (SDCT). MATERIAL AND METHODS: This is a study prospectively examining 336 patients who consulted the ED for wrist trauma. After exclusion criteria were applied, the patients were divided into the study and control groups. Then, SDCT (120 kVp and 100 mAs) and ULDCT (80 kVp and 5 mAs) wrist protocols were applied simultaneously. The images obtained were evaluated for image quality and fracture independently by a radiologist and an emergency medical specialist using a 5-point scale. RESULTS: The effective radiation dose calculated for the control group scans was 41.1 ± 2.1 µSv, whereas the effective radiation dose calculated for the study group scans was 0.5 ± 0.0 µSv. The effective radiation dose of the study group was significantly lower than that of the control group (P < 0.01). The CT images in the study group showed no significant differences in the mean image quality score between observer 1 and observer 2 (3.4 and 4.3, respectively; P = 0.58). Both observers could detect all fractures using the ULDCT images. CONCLUSION: ULDCT provides high-quality images in wrist traumas while reducing the radiation dose by approximately 98% compared to SDCT without any changes in diagnostic accuracy.


Assuntos
Ossos do Carpo/lesões , Fraturas Ósseas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Traumatismos do Punho/diagnóstico por imagem , Adulto , Ossos do Carpo/diagnóstico por imagem , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/lesões , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Fraturas do Rádio/diagnóstico por imagem , Sensibilidade e Especificidade
16.
Turk J Med Sci ; 51(5): 2575-2583, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34333905

RESUMO

BACKGROUND: Necrotizing enterocolitis (NEC) is one of the most important causes of morbidity and mortality in premature infants. Although there are no specific diagnostic tools, the main factors affecting prognosis are clinical and laboratory findings, and early diagnosis and treatment. In this study, we demonstrate the importance of dual-energy computed tomography (DECT) in confirming intestinal ischemia in neonates with NEC. METHODS: Patients diagnosed with NEC in a neonatal intensive care unit were staged according to modified Bell's classification, and DECT was performed on patients with NEC stages 2-A, 2-B and 3-A. According to their DECT reports, these patients were then separated into two groups: those with intestinal ischemia and those without intestinal ischemia. The patients with intestinal ischemia were evaluated using surgical reports, and the other patients were evaluated using clinical findings. RESULTS: DECT was performed in 21 patients with NEC stages 2-A, 2-B and 3-A. Twelve patients (57.1%) without ischemia were followed up without surgery. Nine patients (42.9%) with ischemia on DECT were operated on, and resection and anastomosis or ileostomy and colostomy were performed. DISCUSSION: In patients with NEC, DECT significantly increases overall diagnostic confidence in assessing intestinal necrosis when compared with traditional diagnostic methods.


Assuntos
Enterocolite Necrosante , Doenças do Recém-Nascido , Isquemia Mesentérica , Lactente , Recém-Nascido , Humanos , Enterocolite Necrosante/diagnóstico por imagem , Recém-Nascido Prematuro , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...